€395 fixed price incl. comprehensive report No leak found? Then you pay nothing. 100% risk-free Reimbursed by the insurer 9 out of 10 times FREE quote within 24 hours A solution without chopping and breaking Expert report received within 3 working days No call-out charges Detect all types of leaks Possibilities for minor structural repair
Leak detection logo 2
Nederlands NL English EN

No cure, no pay.

  • 085 080 55 42
Nederlands NL English EN

Bathroom leak detection with thermography? Detect leaks quickly and professionally.

At Ultrices leak detection, you get lightning-fast bathroom leak detection with thermography. Using thermal imaging and an infrared camera, we read temperature differences and heat patterns, entirely non-destructively. We combine thermography with moisture measurement, pipe detection, acoustic detection, endoscopy, and water pressure testing. We trace leaks in showers, baths, sealant joints, drains, underfloor heating, walls, ceilings, and tiled floors. You get exact…

Free Quote

  • Fixed price €395,-
  • 100% Risk-free
  • NEN certified
  • Often reimbursed by insurers
  • No solution? No payment!
  • Report within 3 working days
  • On site within 1 hour
  • Available nationally
  • VCA certified
  • Available 24/7
  • without chopping and breaking work

Instant free quote →

detect bathroom leak 3

🏆Fixed price, no surprises on No cure no pay.
Request a free quote →

At Ultrices leak detection, you get lightning-fast bathroom leak detection with thermography. Using thermal imaging and an infrared camera, we read temperature differences and heat patterns, completely non-destructively.

We combine thermography with moisture measurement, pipe detection, acoustic detection, endoscopy, and water pressure testing. We detect leaks in showers, baths, sealant joints, drains, underfloor heating, walls, ceilings, and tiled floors.

You get exact location determination, less demolition, quick cost savings, and a clear report for insurance to limit water damage. Read Our 5/5 Google reviews for bathroom leak detection with thermography.

Bathroom leak detection with thermography explained

Bathroom leak detection with thermography involves the targeted detection of water leaks in your bathroom using a thermal imaging camera. We use infrared thermography to make invisible temperature differences in tiles, walls, ceilings, and floors visible. Where water seeps, the heat flow changes, and evaporation cools surfaces. This forms a thermal pattern that we flawlessly visualize using professional equipment from FLIR Systems and Testo, among others. In combination with accurate moisture measurement using Tramex and Gann, we obtain a complete picture of the moisture source without any demolition or breaking work. This method aligns with principles from infrared science and building thermography as described in ISO 6781, EN 13187, and ASTM C1060, and delivers reproducible, insurance-substantiated results.

How infrared camera and thermography expose your bathroom leak

Heat flows through materials with varying thermal conductivity and emissivity. Moisture influences these values ​​and causes measurable deviations. Our technicians correct for emissivity and reflections, take into account dew point, latent evaporation, and air currents, and distinguish thermal bridges from actual damp spots. Using a properly calibrated thermal camera and on-site calibration, we identify temperature gradients around pipes, drains, joints, and sealant seams. We combine this with a pressure test on the water line using a manometer, fluorescein dye testing for drains, smoke tests for ventilation leaks, and, if necessary, tracer gas with forming gas for concealed pipes. In this way, we identify the cause, not just the symptom.

Types of bathroom leaks we find with thermal imaging

  • Leak in water pipe: heat patterns around hot and cold water pipes, often under tiled floors or behind walls, visible through local heating or cooling
  • Leak in drain or siphon: cooling patterns due to evaporation under shower tray, bath or washbasin, intensified by test current
  • Joint or sealant seam failure: capillary moisture transport behind tiling with aged silicone sealant or porous joints
  • Underfloor heating related leakage: anomalous thermal strips and moisture plumes in the screed around a damaged loop
  • Concealed cistern and toilet: subtle cold zones behind the frame due to leaking flush mechanism or crack in drain bend

Step-by-step plan for leak detection without demolition or breaking

  1. Intake and preparation: you describe complaints such as damp spots, loose grout, or a high water bill, after which we determine the correct measurement strategy.
  2. Set environmental conditions: optimize ventilation and temperature difference so that thermal contrasts become maximally visible
  3. Thermographic scan: systematic scan of floor, walls, ceiling and risk nodes with FLIR and Testo thermal imaging camera
  4. Verify with additional measurements: fluid measurement, dye or pressure test and, where necessary, endoscopy for visual confirmation
  5. Analysis and diagnosis: interpretation based on emissivity, dew point, material behavior and normative guidelines
  6. Report and advice: within three days you will receive an expert report with the cause, location, images, and repair advice for the insurer and contractor

Leak detection process request

When do you choose thermographic leak detection in the bathroom?

  • Damp patch under or next to the bathroom: visible stain in ceiling or wall adjacent to shower or bath of unclear origin
  • Persistent musty smell: possible mold growth behind tiling due to prolonged moisture
  • High water bill or pressure loss: indication of a leak in supply lines that you cannot see
  • Peeling sealant and joints: water penetrates microcracks in joints and leaves traces in the underlayer
  • New bathroom with warranty: objective baseline measurement and burden of proof for delivery issues or manufacturing defects

Why Ultrices leak detection makes the difference

We operate nationwide with a ninety-nine percent success rate, guarantee coverage, and provide a comprehensive expert report that insurers accept. Our specialists are VCA VOL and NEN 3140 certified, on-site within an hour in emergencies, and reachable by phone or WhatsApp. You benefit from professional detection equipment, no solution, no payment, and a 100% risk-free approach for private and business clients. We are happy to assist you further, and if you would like to delve deeper into finding the causes in the bathroom, please also read our page about everything about detecting bathroom leaks or discover how we work with Leak detection in the bathroom without hacking or breaking..

  • Objective measurement: thermography according to the principles of EN 13187 and ISO 6781 supplemented with ASTM guidelines
  • Combination of techniques: infrared scan, moisture measurement, pressure test, dye and tracer gas where relevant
  • Collaboration with insurers: clear report with thermal images and cause location for quick claims processing
  • Emergency and availabilityWe are available day and night and communicate clearly regarding planning and recovery advice.
  • Transparent certainty: no cure no pay and always without unnecessary demolition work

Practical examples of bathroom thermography

In an apartment in Amsterdam, the thermal imaging camera showed a cool plume next to the shower drain. Fluorescein revealed that the drain connection was leaking. The repair was limited to replacing a coupling without removing tiles. In a 1960s home in Utrecht, we observed a warm streak in the ceiling below the bathroom while showering. That pattern indicated a leaking hot water elbow behind the wall. After a targeted ten-by-ten-centimeter cutout, the leak was repaired within twenty minutes. In a new-build home in Eindhoven, cold patterns along the edge of the bathtub indicated that the sealant joint was not adhering. New sealing and a follow-up check with thermography permanently solved the problem. If you want to know more about the targeted localization of leaks around the shower, check out our approach for Targeted detection of shower leaks or request one directly Free quote for bathroom thermography within 24 hours on.​

For questions or emergencies, contact Ultrices Leak Detection directly at 085 2505 217 or email info@Ultriceslekdetectie.nl. We are ready to assist with bathroom leak detection using thermography, without any demolition work, with an expert report within three days and an approach that demonstrably works.

Frequently asked questions

How does bathroom leak detection with thermography work, and what do you see on a thermal image?

Using an infrared camera such as a FLIR, we analyze temperature patterns in tiling, walls, and floors. Water cools or heats material differently than the surroundings, causing wet zones, leaking hot water pipes, or anomalies around a shower drain to become visible as distinct color contrasts. We correct for emissivity and work with a controlled temperature difference for a sharp thermal image.

We combine thermography with moisture measurements and, if necessary, additional methods such as acoustics or dye testing. This allows you to pinpoint the exact source location without any demolition or breaking work. At Ultrices Leak Detection, we deliver an expert report within three days, featuring clear images and conclusions based on fifteen years of practical experience and VCA VOL and NEN 3140 certification.

What signals betray a hidden bathroom leak that you can detect with thermography?

Watch out for damp patches on the ceiling below the bathroom, dark edges along the shower wall, peeling sealant or porous grout, mold growth, and a musty odor. Warm streaks in the floor near underfloor heating or a constantly ticking water meter may indicate a leaking hot water pipe. Cold streaks around the shower drain or sealing tape often point to failing waterproofing.

If you see a wet spot spreading rapidly or active dripping, call for help immediately. Our 24-hour service is ready, and we are usually on-site within one hour. If you have an emergency, schedule an inspection immediately via quick help with bathroom leak.

Is thermography accurate behind tiles and around the shower drain, and how do you prevent false positive readings?

Yes, provided you execute it correctly. We create a controlled temperature gradient by, for example, briefly running hot or cold water so that the flowing water appears as a clear temperature trace. Our cameras are calibrated, and we use material-specific emissivity settings for reliable interpretation, even behind glaze and dense tilework.

To eliminate noise, we use reference measurements, cross-reference findings with a professional moisture meter, and, if necessary, employ ultrasonic, tracer gas, or camera inspection along the drain. This is how we at Ultrices Leak Detection deliver non-destructive precision with a very high success rate and a No Cure No Pay promise.

How much does bathroom leak detection with thermography cost, and is it covered by your insurance?

The price depends on the situation, accessibility, and required combination measurements. You will receive a free quote within twenty-four hours, and following the investigation, a complete expert report within three days including thermal images, measurements, and a clear cause and repair recommendation. We work nationwide and also handle corporate assignments.

In the Netherlands, tracing costs are often reimbursed under buildings or contents insurance, depending on your policy. We work with insurers and help you with a report that is usually accepted. Always check your terms and conditions. View guide prices via bathroom leak detection costs and read how we report for claims at report for insurance.

Other services